Skip to product information
1/4" Rubberized Tubing Mounts - Bag of 10
1/4" Rubberized Tubing Mounts - Bag of 10

1/4" Rubberized Tubing Mounts - Bag of 10

$12.00
Availability: In stock

Keep your misting lines tidy and protected with these 1/4″ rubberized tubing mounts. They help homeowners and pros route lines cleanly on patios, pergolas, and work areas. The big benefit is a secure, low-profile hold that reduces vibration and keeps installs looking sharp.

What These Mounts Do

These mounts secure and guide 1/4″ OD misting tubing along beams, posts, railings, and walls. The rubberized body cushions the line to reduce vibration and rattle. It also helps prevent scuffs on surfaces and extends the life of your tubing by limiting movement.

Why Choose This Part

Pick these mounts when you want a clean, durable install that protects your gear and looks professional.

  • Secure hold for 1/4″ OD tubing
  • Neat, straight runs with a low-profile look
  • Fast, simple installation with common tools
  • Protects tubing from rub and wear
  • Vibration damping helps reduce rattle
  • Weather-resistant rubberized body
  • Long-lasting grip for indoor or outdoor use

Key Specs

  • Size / Fit: 1/4″ OD tubing
  • Material: Rubberized mount body
  • Connection Type: Mounting clip for 1/4″ tubing
  • Package Contents: Bag of 10 mounts
  • Compatibility: 1/4″ OD misting lines
  • Use Cases: Patios, pergolas, restaurants, warehouses, queue lines

Compatibility & Use Cases

These mounts fit standard 1/4″ OD misting lines used in high-pressure, mid-pressure, and low-pressure systems when sized correctly. Use them to run straight lines along joists, to drop clean feeds to nozzles, or to turn corners without slack. They are a simple way to keep lines tight and out of sight in dining areas, shade structures, and service corridors. For more build-out parts and matching hardware, see Misting Accessories.

Installation Overview

Plan your route, place mounts at even intervals, and press the tubing into each clip. Keep runs straight and avoid sharp bends. After mounting, bring the system up to pressure and check for movement.

Preparation

Measure & Mark Runs

Measure the path for your 1/4″ line and mark mounting points every 12–24 inches. Add extra marks near turns, drops, and nozzles.

Check Tubing Fit & Orientation

Test a mount with a short piece of 1/4″ OD tubing. Make sure the clip seats fully and the opening faces the direction that eases install and service.

Install

Seat the Mounts

Attach mounts to the surface as planned. Keep them aligned so the line runs straight and true.

Secure & Align Tubing

Press the tubing into each mount until it snaps into place. Avoid twisting the line. Keep gentle bends and smooth transitions.

Spacing for Clean Lines

Use 12–18 inch spacing on visible runs for a crisp look. Use 18–24 inch spacing in hidden or sheltered areas. Add a mount near each nozzle or junction.

Pressure Test

Bring System to Operating Pressure

Start the pump and reach normal operating pressure. Watch the mounted sections as the line pressurizes.

Inspect for Rattle & Adjust

Listen and look for any movement, rattle, or scuff points. Add a mount or slightly shift a clip to tighten the run as needed.

Care & Maintenance

Check mounts at the start of each season and after heavy use. Look for wear, looseness, or scuffs. Replace any mount that has lost grip or shows damage. Wipe dust and debris from the line and mounts to keep the system clean.

Troubleshooting

  • Line rattle: Add mounts or reduce spacing near nozzles and turns.
  • Surface scuffing: Reposition the mount or add a mount to remove slack and rubbing.
  • Slack loops: Tighten spacing and realign mounts for straight runs.
  • Clip feels loose: Replace the mount and confirm you are using 1/4″ OD tubing.

Frequently Asked Questions

Will these fit my line?
Yes, they are designed for 1/4″ OD misting tubing.

What surfaces can I mount to?
They work on common flat surfaces like wood, metal, and masonry when the proper fastener is used for the surface.

How far apart should I place mounts?
Plan 12–18 inches for visible runs and 18–24 inches where looks do not matter as much.

Are they suitable outdoors?
Yes, the rubberized body is weather resistant and built for outdoor use.

Can I reuse a mount?
You can remove and reinstall if the clip remains tight. Replace any mount that has lost grip.

Do they reduce vibration?
Yes, the rubberized grip helps damp movement and rattle.

What if I need to return them?
Standard return and warranty terms apply. Contact support for help.

Related Parts & Upgrades

Round out your install with matching parts and fan options for any space. Explore more hardware and fan types suited to your layout and budget.

Shipping, Returns & Support

Orders ship quickly and are packed to protect your parts. Returns are simple if you need to swap or send back unused items. Contact our support team for help selecting parts and compatibility questions.

Product Details

detailed_img

Key Specs
  • Size / Fit: 1/4″ OD tubing
  • Material: Rubberized mount body
  • Connection Type: Mounting clip for 1/4″ tubing
  • Package Contents: Bag of 10 mounts
  • Compatibility: 1/4″ OD misting lines
  • Use Cases: Patios, pergolas, restaurants, warehouses, queue lines

Installation Overview

Plan your route, place mounts at even intervals, and press the tubing into each clip. Keep runs straight and avoid sharp bends. After mounting, bring the system up to pressure and check for movement.

Preparation

Measure & Mark RunsMeasure the path for your 1/4″ line and mark mounting points every 12–24 inches. Add extra marks near turns, drops, and nozzles.

Check Tubing Fit & OrientationTest a mount with a short piece of 1/4″ OD tubing. Make sure the clip seats fully and the opening faces the direction that eases install and service.

product media

Install

Seat the Mounts: Attach mounts to the surface as planned. Keep them aligned so the line runs straight and true.

Secure & Align Tubing: Press the tubing into each mount until it snaps into place. Avoid twisting the line. Keep gentle bends and smooth transitions.

Spacing for Clean Lines: Use 12–18 inch spacing on visible runs for a crisp look. Use 18–24 inch spacing in hidden or sheltered areas. Add a mount near each nozzle or junction.

Pressure Test

Bring System to Operating Pressure: Start the pump and reach normal operating pressure. Watch the mounted sections as the line pressurizes.

Inspect for Rattle & Adjust: Listen and look for any movement, rattle, or scuff points. Add a mount or slightly shift a clip to tighten the run as needed.

product media

Frequently Asked Questions

Yes, they are designed for 1/4″ OD misting tubing.

They work on common flat surfaces like wood, metal, and masonry when the proper fastener is used for the surface.

Plan 12–18 inches for visible runs and 18–24 inches where looks do not matter as much.

Yes, the rubberized body is weather resistant and built for outdoor use.

You can remove and reinstall if the clip remains tight. Replace any mount that has lost grip.

Yes, the rubberized grip helps damp movement and rattle.

Standard return and warranty terms apply. Contact support for help.

Shipping, Returns & Support

Orders are carefully packed to meet the demands of event use and are shipped promptly to help you stay on schedule. If your plans change, returns are straightforward for unused items within the stated return window, making the process hassle-free.


Our support team is always available to assist with every step of your project—from product sizing.

detailed_img